Automated Systems

ILC07

ILC07 automated system

ILC system flow diagram

PermeGear’s Automated Systems incorporate In-Line Cells, a peristaltic pump, a fraction collector, and a heater/circulator into a versatile system for analyzing flux over time. Collection vials are at the option of the user, racks for 20ml 28mm diameter scintillation vials are provided.  When ordering, please advise the size vials you will be using so we can include the correct Vial Racks.  Vials ARE NOT supplied by PermeGear. 

All PermeGear automated diffusion cell systems are based on the continuous flow principle. A multi-channel peristaltic pump draws receptor solution from a reservoir through a distribution manifold and sends it to the In-Line Cells. The cells are warmed to 32ºC by a heater/circulator that pumps water through the Cell Warmer in which the In-Line Cells are located. After filling the receptor chambers of the cells and purging the system of bubbles, the subject compound is then placed in the donor chambers of the cells. From that time, the fluid is collected in the vials of the fraction collector at user set time intervals. The vials are taken for analysis manually after the sampling time has elapsed.

Overall pricing for the ILC07 System is dependent on the configuration of the In-Line Cells used. Email [email protected] for current pricing.

Ordering Information

The components of the ILC07 are as follows:

  • (7) In-Line Cells (many configurations)
  • (1) #10035 Cell Warmer
  • (1) #10027-14 1-liter reservoir & manifold
  • (1) #10033 Fraction Collector
  • (1) #10060 Heater/Circulator
  • (1) #10090-08 Peristaltic Pump

Typical Dimensions

The ILC07 Automated System is compact assembly of integrated components. Once the system is set up, no space on either side of it is required for operation.

Dimensions:

The ILC07’s foot print is 29″/73.7 cm wide x 26″ / 66.0 cm deep x 24″/61.0 cm high and it weighs 120 lbs./54.4 kg

*Height & Weight measurements are given without In-Line Cells

Heater Circulator:
Working Temperature Range: 20ºC to 150ºC
Temperature Stability: +0.03ºC
Flow Rate: 15 L/min

Fraction Collector:
Maximum Samples: 175
Programmable Interval: 1 to 9999 minutes

Cells:
Orifice Diameter: +/- 0.1 mm